TRIDENT® A Carbon Zero Product
P2 Valved Disposable Respirator

Part No.: RTCFFP2V

Standards & Certifications


Certified to:
BSI Logo
AS/NZS 1716: 2012
ID No. BMP 732382

Sizing


Regular
Regular Extended
Length Head Straps
XX Large
RTCFFP2V
RTCFFP2VE

RTCFFP2XXLV

 

Packaging


1 mask per bag
20 masks per inner
240 masks per carton

PortaCount Respirator Fit Testing

PORTACOUNT RESPIRATOR FIT TESTER 8048 KIT

Contact US


TRIDENT™ SUPERIOR MULTILAYER TECHNOLOGY
5 Layers
MultiLayer Technology

Advanced multilayer technology providing protection against mechanically and thermally generated particulates including: dusts, mists, fumes and smoke.

3 PANEL
3 Panel

Three panel design provides structural integrity, form fit seal and optimal comfort.

PROPRIETARY FOAM NOSE SEAL
PROPRIETARY FOAM NOSE SEAL

Proprietary adjustable foam nose pad to ensure consistent optimum facial seal and reduce fogging of eyewear.

EXHALATION VALVE
EXHALATION VALVE

Valved design eliminates the build up of heat and moisture within the breathing zone.

Fits Most
Adapts To Most Faces

Versatile unisex fit suitable for a range of facial shapes and sizes. Effective for many “hard to fit” individuals.

EXCELLENT TEST RESULTS
Fit Test Results

Specialised TRIDENT® respirator seal attains unrivalled PortaCount® fit testing results.

LOW BREATHING RESISTANCE FILTER
LOW BREATHING RESISTANCE

Low breathing resistance, maximizing wearer comfort, durability and life of product.

Use in Conjunction with Other PPE
Use with Other PPE

Designed to be used in conjunction with other mandatory personal protective equipment.

LATEX FREE
Latex Free

Latex free to avoid the risk of developing allergies with repeat exposure.

INDIVIDUALLY PACKAGED
 Batch Numbered and Individually Packaged

Each mask is individually batch numbered and packaged for the ultimate in traceability, portability and hygiene.

Donning & Doffing


How To Apply – Donning
P2 Mask Fitting Instructions - Step 1
Position the respirator in the palm of your hand with the nose strip at your fingertips, ensuring both head straps are untwisted over the back of your hand.
P2 Mask Fitting Instructions - Step 2
Open both the top and bottom panels of the mask and make a bend in the foam nose seal. Place the lower panel under the chin and the upper panel with the foam nose seal over the nose bridge and underneath the eyes.
P2 Mask Fitting Instructions - Step 3
Holding the respirator with one hand, position the top untwisted head strap to the crown of the head.
P2 Mask Fitting Instructions - Step 4
Draw the lower untwisted head strap up and over the face to below the ears and back of the neck. DO NOT CRISS CROSS HEADSTRAPS.
P2 Mask Fitting Instructions - Step 5
With both hands, mould the foam nose seal at the top of the mask to the nose bridge and cheeks ensuring a secure fit and seal.
P2 Mask Fitting Instructions - Step 6
Perform a fit check (see fit check list below). Cover the front of the respirator with both hands. Inhale and exhale sharply.

Fit Check List
  • If air leaks at the nose or cheek areas adjust the foam nose seal until a seal is achieved.
  • If air leaks around the edge of the respirator adjust the head straps and reposition the mask until a seal is achieved.
  • A successful fit check is when there is no air leakage.
  • Always fit check before entering the work area.
  • If a successful fit check cannot be achieved, remove and refit the respirator.
  • If you still cannot obtain a successful fit check, do not enter the work area.

How to Remove – Doffing
Doffing Step 1
The respirator may be contaminated. Touch only the head straps when removing.
Doffing Step 2
Pull the bottom strap over the top of the head.
Doffing Step 3
Pull the top strap over the top of the head.
Doffing Step 4
Dispose of respirator into the appropriate waste receptacle in accordance with site infection control and prevention policies.
Doffing Step 5
Wash and sanitise your hands thoroughly.

Important
  • A fit check must be performed prior to using your disposable respirator.
  • Always read the disposable respirator wearer instructions.
  • Should air leakage occur at respirator edges, adjust the fit to eradicate leakage & perform the above fit check.
  • Should air leakage occur around the nose, adjust the foam nose/cheek support strip to eradicate the leakage & perform the above fit check.
  • When an appropriate fit & seal cannot be achieved do not enter the hazardous environment & follow on-site policy referencing AS/NZS 1716: 2012.

*The end user is responsible for determining the suitability of this product for use in their specific conditions and applications. Sample trialling is recommended and welcomed.

NOTE: To achieve an optimum facial seal, the wearer should be clean-shaven. It is recommended the wearer be fit tested prior to use in accordance with AS/NZS 1715: 2009 and/or onsite requirements. Training on the safe use and limitations of the disposable face mask must be performed in accordance with AS/NZS 1715: 2009 section 2.4.

© Copyright 2021 Industree Group Pty Ltd. All Rights Reserved.    |    Privacy Policy    |    Terms and Conditions A Carbon Zero Company